CADMIUM-CHROMIUM-COPPER,
C18135, PD-135
COMPOSITION
CADMIUM-CHROMIUM-COPPER,
C 18135, PD-135ELEMENT PERCENT MINIMUM MAXIMUM MAXIMUM Copper (Including Silver) 99.2 Remainder Cadmium .4 .2 .6 Chromium .4 .2 .6 Copper (Including Silver and elements with specific limits) -- 99.9 --
PHYSICAL PROPERTIES
CADMIUM-CHROMIUM-COPPER, C 18135, PD-135ENGLISH UNITS
METRIC UNITS
Melting Point
1976°F
1080°C
Density
.323 lb/cu in. @ 68°F
8.84 gm/cm@ 20°C
Specific Gravity
8.94
8.84
Coefficient of Thermal Expansion
.0000098 per °F (68-572°F)
.0000173 per °C (20-300°C)
Thermal Conductivity
210 BTU/sq ft/ft/hr/°F @ 68°F
.87 cal/sq cm/cm/sec/°C @ 20°C
Electrical Resistivity (Annealed)
11.3 Ohms circ mil per ft @ 68°F
1.87 microhm - cm @ 20°C
Electrical Conductivity (Annealed)
92% Copper IACS @ 68°F
.533 megohm cm @ 20°C
Thermal Capacity (Specific Heat)
.09 BTU/lb/°F @ 68°F
.09 cal/gm/°C @ 20°C
Modulus of Elasticity (tension)
20,000 KSI
14,000 kg/sq mm
Modulus of Rigidity (torsion)
7500 KSI
5250 kg/sq mm
Solution Heat Treated, Cold Worked and Aged
MECHANICAL PROPERTIES
CADMIUM-CHROMIUM-COPPER, C 18135, PD-135
For Round, Half Round and Square Wire DESIGNATION TENSILE STRENGTH PERCENT ELONGATION
IN 2 in.
IN 50 mmELECTRICAL CONDUCTIVITY
IACSKSI* MPa** TH01
Solution Heat Treated, Cold Worked (99%)
and Aged70.0 483 10
85 min Values for reference only. Not part of specification.
MECHANICAL PROPERTIES
CADMIUM-CHROMIUM-COPPER, C 18135, PD-135
For Rolled Flat Wire other than Square Wire DESIGNATION TENSILE STRENGTH PERCENT ELONGATION
IN 2 in.
IN 50 mmPERCENT
ELECTRICAL CONDUCTIVITY
IACSKSI* MPa** TD01
Solution Heat Treated, Aged and Cold Worked68.2 470 12
80 Values for reference only. Not part of specification.
* 1 KSI equals 1,000 PSI
** 1 KSI equals 6.894,757 MPaCADMIUM-CHROMIUM-COPPER,
C 18135, PD-135
ASTM Material Specifications